EXAMPLE OF PURIFIER INSTALLED IN THE FACTORY
OF THE COMPANY DOIMO CUCINE SRL
 

ENGLISH TRANSLATION ATTACHED TO THE OFFER No. 940/97

CIRCULAR PURIFIER FILTER

SUBJECT: EMISSION LIMITS OF THE DPR. 203/88 AND FOLLOWING DMs

EMISSION VALUES MUST BE WITHIN THE LIMITS OF THE DM 16.01.95 ATT. 1 PAR. 5 IN ACCORDANCE WITH THE ATTACHMENTS.

IN ADDITION IN ANY OPERATING CONDITION THE EFFICIENCY CO COMBUSTION (CO2/CP+CO2) MUST BE AT LEAST OF 99% AND BE WITHIN THE FOLLOWING EMISSION LIMITS, EXPRESSED FOR A PERCENTAGE OF VOLUME OF OXYGEN IN THE SMOKE OF 11%.

Dust 30 mg/Nmc
HCl 30"
HF 2"
Cd+Hg+Tl 0.1"
Total organic carbon 20"
Sulphur oxides 500"
Nitrogen oxides 500"
Carbon monoxide 150"
PCDD+PCDF (as dioxin equivalent) 0.1 ng/Nmc
Aromatic polycyclic hydrocarbons 0.1 ng/Nmc

 

 


 

STUDIO ENNEPI AMBIENTE
di Nadalin G., Padoin A. e Andreola P.
Centro Balbi Valier - Corte di San Francesco,1 31053 PIEVE DI SOLIGO
Tel. (0438)980630 Fax 842265 e-mail: nadalin@tmn.it
 

 

 

DOIMO CUCINE s.r.l.
Alla c.a. sig. RECH GINO

 

 

SUBJECT Inspection of a wood-shaving boiler in accordance with current regulations (D.M.A.
5 February 1998)
(NOTE: DMA: Decree of the Italian Minister for the Environment)

Operating conditions during analyses
Analyses were carried out, on 17 December 1998, in the steady operating conditions of the plant for recovery of wood-shavings produced by joinery processing which takes place in the factory.
The plant was adjusted by Mr. Giacomo Mosole, legal representative of Mion & Mosole s.r.l., which is the company that installed the filtering plant.

Verification of compliance with the law
With reference to article 11 of the DMA. 5 February 1998, emissions are compliant both in quantity and in quality, as shown in the chemical analyses hereby attached, with the exception of carbon monoxide (CO).

Technical considerations
After an investigation on site, we can express a few consideration on the plant:

- as shown in the chemical analyses that were carried out, all parameters of emission in the out-flowing gas are below the limits of the DMA dated 5 February 1998, with the exception of carbon monoxide (CO).
The boiler mentioned above is not equipped with a suitable system to regulate automatically the air/fuel ratio during starting nor with a plant for continuous control of carbon monoxide, oxygen and temperature in the out-flowing gas. The automatic regulation system is required to achieve the correct combustion of the recycled waste.

- As far as the filtering plant is concerned, we recommend to install an opening-closing system of the filtering plant by-pass regulated by means of a temperature probe (min-max) installed at the exhaust of the multicyclone, in order to avoid ignition and condensation in the sleeves.

- A gangway must be installed to access the sampling point (chimney) of the emission into the atmosphere.

We remain at your disposal for any further clarification you may require.

Best regards,
Pieve di Soligo, 22 February 1999

 

 

 


CHEMICAL ANALYSIS No. 16012/99

SUBJECT: Analysis of emissions into the atmosphere (DPR 203.88)

Client:

DOIMO CUCINE S.r.l.
via Schiavonesca n°78
NERVESA DELLA BATTAGLIA (TV)

Report drawn up on 7 January 99.

 

ANALYSIS OF EMISSIONS INTO THE ATMOSPHERE

WHEREAS: Under request of the company DOIMO CUCINE S.r.l. via Schiavonesca No. 78 - Nervesa della Battaglia (Treviso), on 17 December 1998, we took samples of emissions into the atmosphere of the wood-dust boiler for the production of thermal energy.

SAMPLING REPORT

- Sampling on the analysis points (chimneys) took place on 17 December 1998 from 9.45 am to 12.00, at the factory of the company:

DOIMO CUCINE S.r.l. via Schiavonesca No. 78 - Nervesa della Battaglia (Treviso)

during the normal production cycle of the company with the wood-dust boiler in normal operation.

- Sampling was carried out by personnel trained on the correct usage of the measuring instruments and under the coordination and responsibility of Dr. Marco Carretto.

Analysis and sampling methods:

Flow rate method UNICHIM No.467
Temperature Digital thermometer
Dusts method UNICHIM No.494
Metals method UNICHIM n°723
VOC method UNICHIM n°631
Nitrogen oxides method UNICHIM n°587
Sulfur oxides method UNICHIM n°507
Hydrochloric acid method UNICHIM n°621
Hydrofluoric acid method UNICHIM n°620
Carbon monoxide Dragher titration vial
- Table A describes the sampling points.

- Table B shows the analytical values found in the sampled emissions.

Analysis of the samples, taken from the sampling points, were carried out at the VOCECO Srl laboratories - Marostica (Vicenza)
Analytical methods applied: UNICHIM
Instruments used:
- Darcy tube with differential manometer (Magnehelich)
- Hot-wire anemometer
- Digital thermometer
- Zambelli model ZB2 samplers
- Double cone probe with nozzle for isokinetic sampling
- Glass scrubbers

STANDARD ERRORS IN SAMPLING AND ANALYSIS

Flow rate +/- 15%
Temperature +/- 1°C
Inert dusts +/- 10%
Metals +/- 11%
VOC +/- 10%
Nitrogen oxides +/- 10%
Sulfur oxides +/- 10%
Hydrochloric acid +/- 10%
Carbon monoxide +/- 15
Hydrofluoric acid +/- 10%

TABLE A
(description of emissions into the atmosphere)

Chimney No. 1 Production line and/or department Products used at the time of sampling Dust extraction plant Polluting agents researched
Chimney No. 1
Heating plant with wood dust
Thermal energy Wood dust Cyclone + sleeve filter Dust - HF oxides - CO - VOC - HCI - Metals

TABLE B
ANALIYTICAL EMISSION VALUES

PARAMETERS UOM CHIMNEY No 1
Wood dust heating plant
Flow rate Nmc/h 3620
Temperature of emissions °C 80
Section of chimney mq. 0.1734
Velocity of emissions m/s 7.5
Total dusts mg/Nmc 2.6" **
Metals in the dust    
Cadmium mg/Nmc < 0.001 *
Mercury mg/Nmc < 0.001 *
Arsenic mg/Nmc 0.007 *
Lead mg/Nmc 0.04 *
Chromium mg/Nmc 0.02 *
Copper mg/Nmc 0.03 *
Manganese mg/Nmc 0.01 *
Nickel mg/Nmc < 0.005 *
Sulfur oxides (SO2) mg/Nmc < 20 *
Nitrogen oxides (NO2) mg/Nmc 95 *
Carbon monoxide (CO) mg/Nmc 1140 *
Fluorine inorganic compounds HF) mg/Nmc < 1 *
Chlorine inorganic compounds (HCl) mg/Nmc 3.5 *
VOC as total organic C mg/Nmc 12 *

(*) Emission values have been normalized to a reference value of oxygen content of 11% in the out-flowing gas

(**) in accordance with regulations, emissions into the atmosphere must be below 30 mg/Nm³; with the filter manufactured by Mion & Mosole the value achieved is 2.6 mg/Nm³.

 