| EXAMPLE
OF PURIFIER INSTALLED IN THE FACTORY OF THE COMPANY DOIMO CUCINE SRL |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ENGLISH TRANSLATION ATTACHED TO THE OFFER No. 940/97 CIRCULAR PURIFIER FILTER SUBJECT: EMISSION LIMITS OF THE DPR. 203/88 AND FOLLOWING DMs EMISSION VALUES MUST BE WITHIN THE LIMITS OF THE DM 16.01.95 ATT. 1 PAR. 5 IN ACCORDANCE WITH THE ATTACHMENTS. IN ADDITION IN ANY OPERATING CONDITION THE EFFICIENCY CO COMBUSTION (CO2/CP+CO2) MUST BE AT LEAST OF 99% AND BE WITHIN THE FOLLOWING EMISSION LIMITS, EXPRESSED FOR A PERCENTAGE OF VOLUME OF OXYGEN IN THE SMOKE OF 11%.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating
conditions during analyses Verification
of compliance with the law Technical
considerations - as
shown in the chemical analyses that were carried out, all parameters
of emission in the out-flowing gas are below the limits of the DMA dated
5 February 1998, with the exception of carbon monoxide (CO). - As far as the filtering plant is concerned, we recommend to install an opening-closing system of the filtering plant by-pass regulated by means of a temperature probe (min-max) installed at the exhaust of the multicyclone, in order to avoid ignition and condensation in the sleeves. - A gangway must be installed to access the sampling point (chimney) of the emission into the atmosphere. We remain at your disposal for any further clarification you may require. Best regards,
CHEMICAL ANALYSIS No. 16012/99 SUBJECT: Analysis of emissions into the atmosphere (DPR 203.88) Client: DOIMO
CUCINE S.r.l.
Report drawn up on 7 January 99.
ANALYSIS OF EMISSIONS INTO THE ATMOSPHERE WHEREAS: Under request of the company DOIMO CUCINE S.r.l. via Schiavonesca No. 78 - Nervesa della Battaglia (Treviso), on 17 December 1998, we took samples of emissions into the atmosphere of the wood-dust boiler for the production of thermal energy. SAMPLING REPORT - Sampling on the analysis points (chimneys) took place on 17 December 1998 from 9.45 am to 12.00, at the factory of the company: DOIMO CUCINE S.r.l. via Schiavonesca No. 78 - Nervesa della Battaglia (Treviso) during the normal production cycle of the company with the wood-dust boiler in normal operation. - Sampling was carried out by personnel trained on the correct usage of the measuring instruments and under the coordination and responsibility of Dr. Marco Carretto. Analysis and sampling methods:
- Table B shows the analytical values found in the sampled emissions. Analysis
of the samples, taken from the sampling points, were carried out at
the VOCECO Srl laboratories - Marostica (Vicenza) STANDARD ERRORS IN SAMPLING AND ANALYSIS
TABLE
A
TABLE
B
(*) Emission values have been normalized to a reference value of oxygen content of 11% in the out-flowing gas (**) in
accordance with regulations, emissions into the atmosphere must be below
30 mg/Nm³; with the filter manufactured by Mion & Mosole the
value achieved is 2.6 mg/Nm³. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||